Projects delivered in France and abroad
Filter by division, region or type of assignment.

Kenitra–Marrakech HSL and conventional lines
EALE tender documents for the high-speed line extension to Marrakech and the rework of the 160 km/h conventional lines.

Landes Girondines 400/225 kV substation
New 400/225 kV substation, a key link in connecting the region's renewables to the transmission grid.

Superconducting cables at the Vouillé sidings
World first: reinforcing the power supply of stabling sidings with a superconducting cable.

Villeneuve Demain rolling stock depot
Upgrade of the Villeneuve Prairie depot to host the new RER D and Line R trains.

Marseille Blancarde depot
Return to service and upgrade of the depot's 25 kV substation, out of service since 2016, to supply two workshops again.

Grand Paris Express: traction substation testing, lines 16 and 17
Testing of the rectifier and sub-sectioning substations powering the two automated metro lines.

Marcheprime high-speed train maintenance site
Multi-purpose maintenance and stabling site near Bordeaux: high-speed, regional, metropolitan, intercity, freight and works trains.

Grand Paris Express: temporary operation of line 18
Lock-outs, work permits and train movements during the temporary operation of line 18.

3,200 V traction substations and 20 kV supply points
New 20 kV / 3,200 V substations at Mitry, Aulnay, Saint-Denis and Les Fruitiers.

20 kV supply substations at Mitry, Aulnay and Saint-Denis
Three 20 kV supply substations feeding the 3,200 V substations, from design to acceptance.

EOLE: catenary continuity and insulation testing
Continuity and insulation testing of the catenary for the RER E western extension.

EOLE: EALE substations and catenary in tunnel
Design and works supervision of the EALE substations and catenary in the RER E tunnel.

EOLE: Mantes-la-Jolie depot
MV supply, distribution and lighting of the new RER E train depot.

Grand Paris Express, lines 16 and 17
Traction power simulation of Grand Paris Express lines 16 and 17 to determine the rating of the traction units.

Grand Paris Express: traction simulation of line 15 West
Traction power sizing of the western branch, between Pont de Sèvres and Bécon-les-Bruyères.

Dakar regional express train
55 km line between Dakar and Blaise Diagne airport: traction power and station power systems.

Simandou: Trans-Guinean railway and Moribaya port
Power expertise for the State of Guinea's owner's engineer on the Trans-Guinean railway and Moribaya port.

Abidjan Metro
Procedures, test books and test follow-up for the power installations of Abidjan metro line 1.
Photo : Edison McCullen, CC BY 4.0, via Wikimedia Commons

Nairobi Commuter Rail Network
Electrical feasibility studies for the Nairobi commuter rail network (8 lines), electrified at 25 kV 50 Hz.
Photo : Nairobi123, CC BY-SA 4.0, via Wikimedia Commons

Bois-Bernard 225 kV source substation
New 225 kV source substation shared with Enedis, cut into the Gavrelle–Vendin no. 2 line.

Saint-Ange substation renewal, Paris-Nord
Renewal of the substation backing up Paris-Nord station and feeding the 3.2 kV signalling network.

Temporary 20 kV supply substation, Villeneuve depot
20 kV supply substation keeping the depot running during the Villeneuve Demain works.

1,500 V preconditioning sockets, Avignon depot
New MV substation and three 1,500 V preconditioning sockets for the Marseille–Nice TER Corail coaches.

T13 tram-train, maintenance and stabling depot
Testing and commissioning of the power installations of the T13 tram-train depot.

T12 tram-train, electrical operation of the Massy depot
Lock-outs, electrical operation and energisation of the 1,500 V installations of the T12 depot.

Pierrette 225 kV substation extension
225 kV substation extension to connect an industrial site, under RTE's pilot contract for outsourced engineering.

63 kV substation for a data centre, Villefontaine
63 kV substation connecting a data centre of about 60 MW in Isère to the transmission grid.

SEMAVERT anaerobic digestion plant
MV/LV construction design for an anaerobic digestion plant: MV substation, main LV board, MCC, automation and lighting.

Grenier des Essences solar plant
Load-flow studies and MV sizing for a 93 MWp solar plant in the Yonne.

Lyon–Turin base tunnel: auxiliary power supply
Preliminary design of the power network feeding the auxiliary systems of the France–Italy base tunnel.

EPTIC depot
Three assignments at the EPTIC depot in Clichy for a new maintenance workshop.

Gretz–Troyes electrification
Night-time continuity and insulation testing of the catenary and feeder for the Paris – Troyes line electrification.

La Mure railway
Sizing of the rail-to-rail bonding cables of the heritage line between La Mure and the Grand Balcon.

Figeac computerised signalling centre
Rebuilding the power supplies of Figeac station after the 2018 fire, for the new computerised signalling centre.

Le Boulou: stabling sidings and voltage separation section
Power studies and supply scheme for freight growth towards Spain and the interface with the LFP line.

Centralised network control, West Provence
Remote control of catenary switching devices between Rognac and Saint-Martin-de-Crau on the Paris–Lyon–Marseille line.

EOLE: tunnel ventilation and smoke extraction
Supervision of ventilation works and their power supply in 9 shafts and Porte Maillot station.

EOLE: Nanterre-La Folie site
HV/LV supply and lighting of the switch areas around the new RER E station.

Remote operation of Paris-region stations
Remote control of lighting in 160 Paris-region stations from a central control room.

Rambouillet stabling site for Regio 2N trains
Lighting and power distribution of the upgraded sidings for the new Regio 2N trains.

Line 15 South: power systems of 4 ancillary structures
Power construction design of four ancillary structures between Villejuif and Sèvres.

Le Mans tramway: capacity increase
Adaptation of the Glonnières substation and the depot for trams lengthened from 32 to 44 m.

Saint-Pierre-des-Corps industrial depot
New MV loop and redesign of the power architecture of a heavy maintenance depot.

Electrification of the RATP Charlebourg bus depot
Electrification scenarios for a 211-bus depot, from the grid connection to the chargers.

Mobile rectifier substation, RATP La Villette workshop
Feasibility of a mobile 750 V rectifier substation to charge autonomous tractors during the workshop transition.

Standby generator, Paris-Saint-Lazare station
Overhaul of the control chain of the generator backing up the station's critical systems.

Petit-Thérain site: LV renewal and pad-mounted substation
New main LV board, removal of the standby generator and a 25 kV / 420 V pad-mounted substation replacing the pole transformer.

Busigny substation: earthing grid
Earthing study of a renewed railway substation: grid resistance and step and touch voltages.

Mantes-la-Jolie town hall car park
Compliance upgrade of the HV substation and generator of a 301-space public car park.

Main LV board replacement in a care home, Lallaing
Replacement of all main LV board switchgear in an occupied care home, working at night.

Distribution centre, Paris region
Redesign of the emergency shutdown chain diagram of a rooftop solar plant on a distribution centre.
A project or a tender?